IgG2b, Mouse, Negative Control (FITC)

Cat# I6098-52BN-500ul

Size : 500ul

Brand : US Biological



I6098-52BN IgG2b, Mouse, Negative Control (FITC)

Clone Type
Polyclonal
Host
mouse
Source
mouse
Isotype
IgG2b
Grade
Highly Purified
Applications
FC IF
Crossreactivity
Hu
Shipping Temp
Blue Ice
Storage Temp
4°C

I6098-52BN is a control to approximate the amount of nonspecific binding of FITC conjugated mouse IgG2b monoclonal antibodies to human lymphocytes in a whole blood procedure with analysis by flow cytometry. It is suitable for use as negative isotype control for FC analysis using the primary antibody H6098-52A (anti-HLA Class 1 Antigen B27 (FITC) antibody). ||Applications:|Suitable for use in Flow Cytometry. Other applications have not been tested.||Recommended Dilution:|Flow Cytometry: 1ug (10ul) per 100ul whole blood.|Optimal dilutions to be determined by the researcher.||FITC/Protein Ratio: |6.0||Storage and Stability:|Store product at 4°C if to be used immediately within two weeks. For long-term storage, aliquot to avoid repeated freezing and thawing and store at -20°C. Aliquots are stable at -20°C for 12 months after receipt. Dilute required amount only prior to immediate use. Further dilutions can be made in assay buffer. |Caution: FITC conjugates are sensitive to light. For maximum recovery of product, centrifuge the original vial after thawing and prior to removing the cap.

Applications
Product Type: Mab|Isotype: IgG2b|Clone No: MPC-11|Host: mouse|Source: mouse|Concentration: ~0.1mg/ml|Form: Supplied as a liquid. Labeled with fluorescein isothiocyanate (FITC). |Purity: Purified by Ion Exchange chromatography.||Important Note: This product as supplied is intended for research use only, not for use in human, therapeutic or diagnostic applications without the expressed written authorization of United States Biological.
Form
Supplied as a liquid. Labeled with fluorescein isothiocyanate (FITC).
Purity
Purified by Ion Exchange chromatography.
References
1. NCCLS Tentative Standard. "Leukocyte Differential Counting" Publication Number H20-T, NCCLS, Vol. 4, No. 11 (1984). 2. Pei, R., et al., Amonospecific HLA-27 fluorescein isothiocyanate conjugated monoclonal antibody for rapid, simple and accurate HLA-B27 typing. Tissue Antigen 41: 200-203 (1993). 3. Pei, R., Woo, G. and Lee, J.H. "Detection of blood chimerism at a frequency of one per thousand by flow cytometry. Visuals of the clinical histocompatibility workshop", Paul I. Terasaki, Ed., pp.73-74 (1995). 4. Pei, R., Chen, T., Orpilla, J. and Lee, J.H. "A simultaneous negative and positive selection method that can detect chimerism at a frequency of 1 per 10,000 by flow cytometry", Tissue Antigens 50:197-201 (1997).